Validation of Electrical Test

dhaas is testing TDR2 number 008, FM


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 110.00000 B +3.3 108.00000
A +5.6S 81.00000 B +5.6S 87.00000
A +5.6K 51.00000 B +5.6K 52.00000
A -2.0S 10.00000 B -2.0S 9.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.437 B +3.3 3.424
A +5.6S 5.178 B +5.6S 5.212
A +5.6K 5.227 B +5.6K 5.178
A -2.0K 3.439 B -2.0K -1.988
A +2.0K 2.155 B +2.0K 2.157
A -2.0S -1.992 B -2.0S -1.992
A +2.0S 2.155 B +2.0S 2.157

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 404.0 B +3.3 434.0
A +5.6S 147.0 B +5.6S 154.0
A +5.6K 115.0 B +5.6K 116.0

Comments:

oops, went to wrong testpoint for -2.0V K A, measured the 3.3, but -2.0 is ok also

Data files of this test:

./FM_008_20060622_test1.log
./FM_008_20060622_test1_ssf.eps
./FM_008_20060622_test1_ssf1.dat
./FM_008_20060622_test1_ssf2.dat
./FM_008_20060622_test1_ssf3.dat
./FM_008_20060622_test1_ssf4.dat
./FM_008_20060622_test1_ssf5.dat
./FM_008_20060622_test1_ssf6.dat