Validation of Electrical Test

dhaas is testing TDR2 number 010, FM


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 109.00000 B +3.3 108.00000
A +5.6S 95.00000 B +5.6S 87.00000
A +5.6K 56.00000 B +5.6K 53.00000
A -2.0S 9.00000 B -2.0S 9.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.437 B +3.3 3.420
A +5.6S 0.207 B +5.6S 5.195
A +5.6K 5.180 B +5.6K 5.184
A -2.0K -2.003 B -2.0K -2.005
A +2.0K 2.151 B +2.0K 2.150
A -2.0S -1.999 B -2.0S -2.001
A +2.0S 2.151 B +2.0S 2.150

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 297.0 B +3.3 434.0
A +5.6S 0 B +5.6S 130.0
A +5.6K 128.0 B +5.6K 128.0

Comments:

voltages are ok, remeasured 5.6 S A manually, probe made only a bad contact! ssfs ok as well

Data files of this test:

./FM_010_20060621_test1.log
./FM_010_20060621_test1_ssf.eps
./FM_010_20060621_test1_ssf1.dat
./FM_010_20060621_test1_ssf2.dat
./FM_010_20060621_test1_ssf3.dat
./FM_010_20060621_test1_ssf4.dat
./FM_010_20060621_test1_ssf5.dat
./FM_010_20060621_test1_ssf6.dat