Validation of Electrical Test
dhaas is testing TDR2 number 016, FM
-> AMSWire/CDP Test
Power consumptions
Volt | Power (mA) | Volt | Power [mA] |
A +3.3 | 111.00000 | B +3.3 | 95.00000 |
A +5.6S | 90.00000 | B +5.6S | 79.00000 |
A +5.6K | 51.00000 | B +5.6K | 50.00000 |
A -2.0S | 10.00000 | B -2.0S | 10.00000 |
A -2.0K | 5.00000 | B -2.0K | 5.00000 |
A +2.0S | 0.00000 | B +2.0S | 0.00000 |
A +2.0K | 0.00000 | B +2.0K | 0.00000 |
Onboard Voltages
Volt nom. | Onboard Volt | Volt nom. | Onboard Volt |
A +3.3 | 3.437 | B +3.3 | 3.426 |
A +5.6S | 5.224 | B +5.6S | 5.224 |
A +5.6K | 5.184 | B +5.6K | 5.218 |
A -2.0K | -2.007 | B -2.0K | -2.005 |
A +2.0K | 2.167 | B +2.0K | 2.167 |
A -2.0S | -1.999 | B -2.0S | -2.003 |
A +2.0S | 2.170 | B +2.0S | 2.167 |
SSF Voltages
SSF | Cut Value (mA) | SSF | Cut Value (mA) |
A +3.3 | 95.0 | B +3.3 | 145.0 |
A +5.6S | 127.0 | B +5.6S | 145.0 |
A +5.6K | 117.0 | B +5.6K | 119.0 |
Comments:
SSFs +3.3 are ok, but show up strange in the plot
Data files of this test:
./FM_016_20060925_test1.log
./FM_016_20060925_test1_ssf.eps
./FM_016_20060925_test1_ssf1.dat
./FM_016_20060925_test1_ssf2.dat
./FM_016_20060925_test1_ssf3.dat
./FM_016_20060925_test1_ssf4.dat
./FM_016_20060925_test1_ssf5.dat
./FM_016_20060925_test1_ssf6.dat