Validation of Electrical Test

dhaas is testing TDR2 number 027, FM


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 106.00000 B +3.3 109.00000
A +5.6S 83.00000 B +5.6S 91.00000
A +5.6K 51.00000 B +5.6K 53.00000
A -2.0S 10.00000 B -2.0S 10.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.437 B +3.3 3.420
A +5.6S 5.203 B +5.6S 5.227
A +5.6K 5.212 B +5.6K 5.214
A -2.0K -2.009 B -2.0K -2.007
A +2.0K 2.165 B +2.0K 2.165
A -2.0S -2.003 B -2.0S -2.005
A +2.0S 2.163 B +2.0S 0.000

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 434.0 B +3.3 434.0
A +5.6S 146.0 B +5.6S 144.0
A +5.6K 135.0 B +5.6K 99.0

Comments:

+2.0 V S, Side B is ok (+2.1 V), bad probe contact

Data files of this test:

./FM_027_20060922_test1.log
./FM_027_20060922_test1_ssf.eps
./FM_027_20060922_test1_ssf1.dat
./FM_027_20060922_test1_ssf2.dat
./FM_027_20060922_test1_ssf3.dat
./FM_027_20060922_test1_ssf4.dat
./FM_027_20060922_test1_ssf5.dat
./FM_027_20060922_test1_ssf6.dat