Validation of Electrical Test

dhaas is testing TDR2 number 050, FM


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 109.00000 B +3.3 107.00000
A +5.6S 92.00000 B +5.6S 97.00000
A +5.6K 54.00000 B +5.6K 56.00000
A -2.0S 9.00000 B -2.0S 9.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.430 B +3.3 3.418
A +5.6S 5.222 B +5.6S 5.218
A +5.6K 5.182 B +5.6K 5.182
A -2.0K -2.022 B -2.0K 0.013
A +2.0K 2.165 B +2.0K 2.161
A -2.0S -2.018 B -2.0S -2.018
A +2.0S 2.163 B +2.0S 2.161

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 437.0 B +3.3 371.0
A +5.6S 149.0 B +5.6S 0
A +5.6K 122.0 B +5.6K 125.0

Comments:

-2.0 K, Side B is ok (-2.0 V measured by hand), bad probe contact SSF +5.6 S, Side B cuts at 142 mA, and is ok as well

Data files of this test:

./FM_050_20060920_test1.log
./FM_050_20060920_test1_ssf.eps
./FM_050_20060920_test1_ssf1.dat
./FM_050_20060920_test1_ssf2.dat
./FM_050_20060920_test1_ssf3.dat
./FM_050_20060920_test1_ssf4.dat
./FM_050_20060920_test1_ssf5.dat
./FM_050_20060920_test1_ssf6.dat