Validation of Electrical Test

dhaas is testing TDR2 number 063, FM


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 107.00000 B +3.3 108.00000
A +5.6S 36.00000 B +5.6S 81.00000
A +5.6K 53.00000 B +5.6K 50.00000
A -2.0S 9.00000 B -2.0S 10.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.443 B +3.3 3.430
A +5.6S 0.185 B +5.6S 5.241
A +5.6K 5.229 B +5.6K 5.218
A -2.0K -1.982 B -2.0K -1.986
A +2.0K 2.180 B +2.0K 2.180
A -2.0S -1.980 B -2.0S -1.982
A +2.0S 2.182 B +2.0S 2.180

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 B +3.3
A +5.6S B +5.6S
A +5.6K B +5.6K

Comments:

consumption on +5.6 V S, Side A is far too low, short circuit?? can't check either voltager or SSF, testhole is glued... (main problem??)

Data files of this test:

./FM_063_20060921_test1.log
./FM_063_20060921_test1_ssf.eps
./FM_063_20060921_test1_ssf1.dat
./FM_063_20060921_test1_ssf2.dat
./FM_063_20060921_test1_ssf3.dat
./FM_063_20060921_test1_ssf4.dat
./FM_063_20060921_test1_ssf5.dat
./FM_063_20060921_test1_ssf6.dat