Validation of Electrical Test

dhaas is testing TDR2 number 074, FM


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 107.00000 B +3.3 106.00000
A +5.6S 91.00000 B +5.6S 87.00000
A +5.6K 55.00000 B +5.6K 52.00000
A -2.0S 9.00000 B -2.0S 9.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.437 B +3.3 3.420
A +5.6S 5.207 B +5.6S 5.207
A +5.6K 5.197 B +5.6K 5.207
A -2.0K -2.011 B -2.0K -2.009
A +2.0K 2.163 B +2.0K 2.167
A -2.0S -2.005 B -2.0S -2.005
A +2.0S 2.161 B +2.0S 2.163

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 435.0 B +3.3 371.0
A +5.6S 154.0 B +5.6S 148.0
A +5.6K 55.0 B +5.6K 113.0

Comments:

SSF +5.6 K, Side A cuts correctly at 124 mA, but I removed the probe too early

Data files of this test:

./FM_074_20060921_test1.log
./FM_074_20060921_test1_ssf.eps
./FM_074_20060921_test1_ssf1.dat
./FM_074_20060921_test1_ssf2.dat
./FM_074_20060921_test1_ssf3.dat
./FM_074_20060921_test1_ssf4.dat
./FM_074_20060921_test1_ssf5.dat
./FM_074_20060921_test1_ssf6.dat