Validation of Electrical Test

dhaas is testing TDR2 number 089, FM


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 112.00000 B +3.3 110.00000
A +5.6S 80.00000 B +5.6S 87.00000
A +5.6K 49.00000 B +5.6K 53.00000
A -2.0S 104.00000 B -2.0S 8.00000
A -2.0K 5.00000 B -2.0K 4.00000
A +2.0S 95.00000 B +2.0S -0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.432 B +3.3 3.418
A +5.6S 5.199 B +5.6S 5.218
A +5.6K 5.168 B +5.6K 5.187
A -2.0K -2.001 B -2.0K -1.999
A +2.0K 2.163 B +2.0K 2.159
A -2.0S -1.959 B -2.0S -1.973
A +2.0S 2.125 B +2.0S 0.000

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 440.0 B +3.3 463.0
A +5.6S 144.0 B +5.6S 148.0
A +5.6K 129.0 B +5.6K 129.0

Comments:

Consumption on -2.0 S, Side a is far too high! (104 instead of 10 mA) Voltage +2.0 S, Side B is ok (2.2 V)

Data files of this test:

./FM_089_20070118_test1.log
./FM_089_20070118_test1_ssf.eps
./FM_089_20070118_test1_ssf1.dat
./FM_089_20070118_test1_ssf2.dat
./FM_089_20070118_test1_ssf3.dat
./FM_089_20070118_test1_ssf4.dat
./FM_089_20070118_test1_ssf5.dat
./FM_089_20070118_test1_ssf6.dat