Validation of Electrical Test

dhaas is testing TDR2 number 1, QM2


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 114.00000 B +3.3 111.00000
A +5.6S 83.00000 B +5.6S 78.00000
A +5.6K 51.00000 B +5.6K 49.00000
A -2.0S 9.00000 B -2.0S 9.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.342 B +3.3 3.342
A +5.6S 5.157 B +5.6S 5.151
A +5.6K 5.157 B +5.6K 5.178
A -2.0K -2.007 B -2.0K -2.005
A +2.0K 2.140 B +2.0K 2.140
A -2.0S -2.138 B -2.0S -2.138
A +2.0S 2.150 B +2.0S 2.150

SSF Voltages

SSF Cut Value SSF Cut Value
A +3.3 443.0 B +3.3 438.0
A +5.6S 146.0 B +5.6S 146.0
A +5.6K 127.0 B +5.6K 128.0

Comments:

Data files of this test:

./QM2_001_20040225_test1.log
./QM2_001_20040225_test1_ssf.eps
./QM2_001_20040225_test1_ssf1.dat
./QM2_001_20040225_test1_ssf2.dat
./QM2_001_20040225_test1_ssf3.dat
./QM2_001_20040225_test1_ssf4.dat
./QM2_001_20040225_test1_ssf5.dat
./QM2_001_20040225_test1_ssf6.dat