Validation of Electrical Test

dhaas is testing TDR2 number 3, QM2


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 109.00000 B +3.3 110.00000
A +5.6S 91.00000 B +5.6S 80.00000
A +5.6K 54.00000 B +5.6K 51.00000
A -2.0S 9.00000 B -2.0S 10.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.346 B +3.3 3.342
A +5.6S 5.167 B +5.6S 5.163
A +5.6K 5.178 B +5.6K 5.170
A -2.0K -2.007 B -2.0K -2.007
A +2.0K 2.140 B +2.0K 2.140
A -2.0S -2.140 B -2.0S -2.140
A +2.0S 2.150 B +2.0S 2.150

SSF Voltages

SSF Cut Value SSF Cut Value
A +3.3 436.0 B +3.3 436.0
A +5.6S 149.0 B +5.6S 145.0
A +5.6K 133.0 B +5.6K 119.0

Comments:

Data files of this test:

./QM2_003_20040225_test1.log
./QM2_003_20040225_test1_ssf.eps
./QM2_003_20040225_test1_ssf1.dat
./QM2_003_20040225_test1_ssf2.dat
./QM2_003_20040225_test1_ssf3.dat
./QM2_003_20040225_test1_ssf4.dat
./QM2_003_20040225_test1_ssf5.dat
./QM2_003_20040225_test1_ssf6.dat