Validation of Electrical Test

dhaas is testing TDR2 number 3, QM2


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 108.00000 B +3.3 102.00000
A +5.6S 88.00000 B +5.6S 87.00000
A +5.6K 52.00000 B +5.6K 54.00000
A -2.0S 9.00000 B -2.0S 10.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 0.139 B +3.3 3.348
A +5.6S 5.170 B +5.6S 5.163
A +5.6K 5.182 B +5.6K 5.170
A -2.0K -2.007 B -2.0K -2.007
A +2.0K 2.144 B +2.0K 2.144
A -2.0S -2.138 B -2.0S -2.138
A +2.0S 2.153 B +2.0S 2.153

SSF Voltages

SSF Cut Value (mA) SSF Cut Value (mA)
A +3.3 166.0 B +3.3 436.0
A +5.6S 151.0 B +5.6S 144.0
A +5.6K 132.0 B +5.6K 125.0

Comments:

testpoints are coated, so sometimes no contact for measurement, but otherwise ok

Data files of this test:

./QM2_003_20040302_test1.log
./QM2_003_20040302_test1_ssf.eps
./QM2_003_20040302_test1_ssf1.dat
./QM2_003_20040302_test1_ssf2.dat
./QM2_003_20040302_test1_ssf3.dat
./QM2_003_20040302_test1_ssf4.dat
./QM2_003_20040302_test1_ssf5.dat
./QM2_003_20040302_test1_ssf6.dat