Validation of Electrical Test

dhaas is testing TDR2 number 6, QM2


-> AMSWire/CDP Test

Power consumptions

Volt Power (mA) Volt Power [mA]
A +3.3 108.00000 B +3.3 108.00000
A +5.6S 88.00000 B +5.6S 89.00000
A +5.6K 51.00000 B +5.6K 54.00000
A -2.0S 10.00000 B -2.0S 10.00000
A -2.0K 5.00000 B -2.0K 5.00000
A +2.0S 0.00000 B +2.0S 0.00000
A +2.0K 0.00000 B +2.0K 0.00000

Onboard Voltages

Volt nom. Onboard Volt Volt nom. Onboard Volt
A +3.3 3.346 B +3.3 3.344
A +5.6S 5.174 B +5.6S 5.187
A +5.6K 5.159 B +5.6K 5.182
A -2.0K -2.007 B -2.0K -2.007
A +2.0K 2.140 B +2.0K 2.140
A -2.0S -2.140 B -2.0S -2.140
A +2.0S 2.150 B +2.0S 2.150

SSF Voltages

SSF Cut Value SSF Cut Value
A +3.3 0 B +3.3 434.0
A +5.6S 143.0 B +5.6S 139.0
A +5.6K 123.0 B +5.6K 129.0

Comments:

SSF +3.3 A did not switch off here, but during repeated manual tests it switched off at ~400mA as foreseen