Validation of Electrical Test
dhaas is testing TDR2 number 002, FM
-> AMSWire/CDP Test
Power consumptions
Volt | Power (mA) | Volt | Power [mA] |
A +3.3 | 109.00000 | B +3.3 | 103.00000 |
A +5.6S | 85.00000 | B +5.6S | 79.00000 |
A +5.6K | 50.00000 | B +5.6K | 51.00000 |
A -2.0S | 10.00000 | B -2.0S | 10.00000 |
A -2.0K | 5.00000 | B -2.0K | 5.00000 |
A +2.0S | 0.00000 | B +2.0S | 0.00000 |
A +2.0K | 0.00000 | B +2.0K | 0.00000 |
Onboard Voltages
Volt nom. | Onboard Volt | Volt nom. | Onboard Volt |
A +3.3 | 3.441 | B +3.3 | 3.426 |
A +5.6S | 5.214 | B +5.6S | 5.214 |
A +5.6K | 5.197 | B +5.6K | 5.186 |
A -2.0K | -1.990 | B -2.0K | -1.994 |
A +2.0K | 2.159 | B +2.0K | 2.159 |
A -2.0S | -1.990 | B -2.0S | -1.990 |
A +2.0S | 2.159 | B +2.0S | 2.159 |
SSF Voltages
SSF | Cut Value (mA) | SSF | Cut Value (mA) |
A +3.3 | 352.0 | B +3.3 | 434.0 |
A +5.6S | 149.0 | B +5.6S | 149.0 |
A +5.6K | 126.0 | B +5.6K | 123.0 |
Comments:
SSF for 3.3A cuts a little early, but still ok
Data files of this test:
./FM_002_20060621_test1.log
./FM_002_20060621_test1_ssf.eps
./FM_002_20060621_test1_ssf1.dat
./FM_002_20060621_test1_ssf2.dat
./FM_002_20060621_test1_ssf3.dat
./FM_002_20060621_test1_ssf4.dat
./FM_002_20060621_test1_ssf5.dat
./FM_002_20060621_test1_ssf6.dat